Our Products – Soguitrel https://soguitrel.com Let's Transform The World! Thu, 27 Jun 2024 09:57:21 +0000 en-US hourly 1 https://wordpress.org/?v=6.6.2 https://soguitrel.com/wp-content/uploads/2024/09/soguitrel-icon-100x100.png Our Products – Soguitrel https://soguitrel.com 32 32 DISTRIBUTION TRANSFORMER https://soguitrel.com/product/distribution-transformer/ https://soguitrel.com/product/distribution-transformer/#respond Thu, 22 Jun 2023 12:30:14 +0000 https://sgtectransformers.com/?post_type=product&p=1763 3.3kV, 6.3kV, 6.6kV, 11kV (13.2kV/13.8kV/15kV/20kV/22kV/33kV/34.5kV) to 0.38kV, 0.4kV, 0.42kV, 0.44kV up to 25000kVA

With or without on-load-tap-charger type distribution transformer is made of high-quality silicon-steel sheets, and laminated by steps, it is advantageous in low loss, low noise, low voltage partial discharge and high anti-short circuit capacity.

The dynamical and thermal stability of this transformer, of which the coils are winded by high-quality oxygen-free copper wire as well as used pre-compressing brackets processes and interior and exterior structure.

  • Rated voltage:
    • 3kV
    • 3kV
    • 6kV
    • 11kV
    • 2kV
    • 8kV
    • 15kV
    • 20kV
    • 22kV
    • 33kV
    • 5kV
  • Rated power:
    • 50kvA~2500kva
  • Two windings or three windings
  • On-load or no-load voltage tapping changer
  • Frequency:
    • 50HZ /60HZ
  • Vector group:
    • Dyn5
    • Dyn11
    • Ynd11
    • Yna0d11
    • or others
  • Cooling:
    • ONAN
    • ONAF
    • OFAF
  • Tap changer: Optional
  • Rating plate: Yes (Rockwell brand or Customer brand)
  • Corrugated refrigeration panels: Yes (Four sides of the transformer shell)

PARTS

  • Oil draining valve
  • Oil level indicator
  • Thermometer
  • Oil conservator
  • Relay

STANDARD

  • IEC 60076 power transformer
  • 3, 5-2003 power transformer power transformer
  • GB/T6457-1999 3-phase oil immersed power transformer technical parameters and requirement
  • Transformer normal service condition:
  • Type: Outdoor type
  • Normal use environment: Elevation less than 1000m;
    • Temperature range:-25 °C- +40°C
  • Especial environment: Elevation more than 1000m;
    • Temperature range:-45 °C- +40°C
  • Installation site: Nothing corrode air, noting obvious dirty mark
]]>
https://soguitrel.com/product/distribution-transformer/feed/ 0
LIGHTING ARRESTERS https://soguitrel.com/product/lighting-arresters/ https://soguitrel.com/product/lighting-arresters/#respond Thu, 22 Jun 2023 12:25:56 +0000 https://sgtectransformers.com/?post_type=product&p=1760 Lighting arresters provide active over voltage protection that contributes directly to improved reliability of your system, reducing lost minutes and protecting expensive assets.

The arrester has been designed and type tested according to IEC60099-4:2004 standard.

]]>
https://soguitrel.com/product/lighting-arresters/feed/ 0
DROP OUT FUSES https://soguitrel.com/product/drop-out-fuses/ https://soguitrel.com/product/drop-out-fuses/#respond Thu, 22 Jun 2023 12:24:31 +0000 https://sgtectransformers.com/?post_type=product&p=1759 We are instrumental in supplying and trading a wide gamut of silicon composite drop out fuses. Manufactured using high quality raw material, all our products are designed in compliance with international quality standards.

  • Rated Voltage Ur, kV
]]>
https://soguitrel.com/product/drop-out-fuses/feed/ 0
COMPOSITE INSULATORS https://soguitrel.com/product/composite-insulators/ https://soguitrel.com/product/composite-insulators/#respond Thu, 22 Jun 2023 12:20:48 +0000 https://sgtectransformers.com/?post_type=product&p=1757
  • Composite insulators made of the highest quality silicon rubbers
  • Types: Composite tension insulator, composite suspension insulator, braced insulator, substation composite post insulators, composite pin insulators, railway composite insulator
  • Rods made out of ECR-FRP
  • Design up to customer requirements
  • Fast delivery times
  • SUSPENSION COMPOSITE INSULATOR

    • From 10-750 KV
    • Max SML: 500 kN
    • Creepage distance according to customer requirement
    • Standards:
      • IEC 61952
      • IEC 61109
    • End fittings:
      • Hot deep galvanized steel
      • IEC 60120, IEC 6047, IEC 61466-1

    PIN TENSION COMPOSITE INSULATOR

    • Voltage level: 3 – 52 kV
    • SML: 200 kN
    • SCL: 20 kN
    • Connecting Length: up to 2 m
    • Standards
      • IEC 61952
      • IEC 61109
    • End fittings:
      • Hot deep galvanized steel
      • IEC 61109
      • or according to costumer requirement
    ]]>
    https://soguitrel.com/product/composite-insulators/feed/ 0
    COMPACT SUBSTATION https://soguitrel.com/product/compact-substation/ https://soguitrel.com/product/compact-substation/#respond Sun, 22 Jan 2023 12:28:55 +0000 https://sgtectransformers.com/?post_type=product&p=1762

     

    Our compact substation units have high-fire-point fluid, providing fire safety benefits, and a projected life well beyond that of a traditional mineral-oil transformer.

    These efficient and cost-effective transformers use Envirotemp™ FR3™ fluid. Envirotran transformers are manufactured in 50 – 2, 500kVA, in primary voltage classes of 11kV, 15 kV, 25 kV and 35 kV.

    Three-phase, pad-mounted transformers, for use on underground power distribution systems, are best suited for commercial applications in public access areas and where underground service is required. These transformers meet modern design requirements for flexibility and provide a visually pleasing installation.

    Construction allows installation in locations accessible to the general public without the need for protective fencing or vaults. These units are ideally suited for apartment buildings, schools, hospitals, shopping centres, commercial buildings, or industrial sites.

    ENVIRONMENTAL INFORMATION

    • Sealed tank construction
    • Special waste disposal considerations
    • Insulation temperature limit: 120 °C
    • Temperature rise: 65 °C (standard); 55 °C or 55/65 °C (optional)

    SPECIAL DESIGN OPTIONS

    • Special sound requirements
    • Special altitude requirements
    • Retrofit designs
    • Higher efficiency requirements
    • Special ambient conditions

    APPLICABLE STANDARD

    • IEEE C57.12.00: Standard general requirements for liquid-immersed distribution, power, and regulating transformers
    • IEEE C57.12.34: Requirements for pad-mounted, compartmental-type, self-cooled, three-phase distribution transformers, 2, 500 KvA and smaller: high voltage, 34, 500 grdy/ 19, 920v and below; low voltage, 480v and below
    • IEEE C57.12.28: Standard for pad-mounted equipment, enclosure integrity
    • IEEE C57.12.70: Standard for terminal markings and connections for distribution and power transformers
    • IEEE C57.12.80: Standard terminology for power and distribution transformers
    • IEEE C57.12.90: Standard test code for liquid-immersed distribution, short-circuit testing of distribution and power transformers
    • IEEE C57.13: Requirements for instrument transformers
    • ANSI/IEEE 386: Separable insulated connector systems for power distribution systems above 600v.
    • ASTM D877: Test method for dielectric breakdown voltage of insulating liquids using disk electrodes.
    • NEMA AB1: Moulded case circuit breakers.
    • NEMA TR1: Transformers, regulators, and reactors.

     

    ]]>
    https://soguitrel.com/product/compact-substation/feed/ 0